Cooperation partner
Medical Gloves | FDA- surgical gloves specifications printable ,2022-6-18 · Medical gloves are one part of an infection-control strategy. Medical gloves are disposable and include examination gloves, surgical gloves, and medical gloves for handling chemotherapy agents ...SURGICAL GLOVES - Sempermed - PDF CatalogsSEMPERMED SURGICAL GLOVES YOUR HANDS IN BEST HANDS With more than 90 years of research and production know-how, surgical gloves by Sempermed stand for supreme safety and professionalism. Above all, the Sempermed surgical gloves excel with their unique combination of perfect grip, optimal tactile properties and maximum comfort.
2021-11-11 · Specifications Performance Requirements - AQL ... Glove Specifications Quantity: 4 boxes/ case 50 pairs/ box (by weight) Packaging 71000 Series Latex Surgical Gloves Before Aging After Aging at 100C for 22 hrs Tensile Strength Mpa (minimum) 24 18 Ultimate Elongation % (minimum) 750 560 Stress at 500% elongation (max) 5.5Mpa ...
2022-6-16 · 8-24 Protexis™ Surgical Glove Portfolio 26 Environmental stewardship 27-31 Testing standards and data 32-36 Product quick reference. Non-latex polyisoprene. 9rotexis™ PI P 10rotexis™ PI with Neu-Thera® P 11rotexis™ PI Classic P 12rotexis™ PI Blue with Neu-Thera® P
2021-9-9 · Specifications For Latex Orthopaedic Surgical Gloves - Sterile PHYSICAL DIMENSIONS Glove Size Palm Width (mm) Length (mm) 6.0 76 ± 6 Min.280 6.5 83 ± 6 Min.280 7.0 89 ± 6 Min.280 7.5 95 ± 6 Min.280 8.0 102 ± 6 Min.280 8.5 108 ±6 Min.280 9.0 114 ± 6 Min.280 Thickness Location of Thickness Measurements Double Wall (mm)
2022-6-16 · • Designed to be comfortable and reliable for any type of surgical procedure • Thicker than Protexis® PI Surgical Gloves • Synthetic, not made with natural rubber latex Protexis® PI Classic See Appendix page 29 for complete testing standards This product is not made with natural rubber latex 1. Thickness tested in accordance with ASTM D ...
McKesson Brand 14-6974C - McKesson Medical-Surgical. McKesson Confiderm® 3.5C Nitrile Exam Gloves Small Powder-Free Tested for use with Chemotherapy Drugs using ASTM D6978-05. Gloves used for protection against chemotherapy drug exposure must be selected specifically for the type of glove being used.
2018-3-14 · • Gloves before opened for use shall be stored in dark, cool and dry place. • Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF. • Gloves need to be stored at the areas with good air ventilation. • Gloves need to be shielded from direct sunlight and fluorescent lighting.
SQBF09 Qualatrile SENS! Blue Nitrile 9” Powder-Free Gloves ... SQBF09 Qualatrile SENS! Blue Nitrile 9” Powder-Free Gloves Quality Assurance Conformity ASTM D6319 – 10 (2015) ASTM D6124 ASTM D412 U.S. Pharmacopeia-National Formulary (USP-NF) ASTM D573 ANSI ESD S 11.11-1993 ASTM D3577 – 09(2015) ASD STN 11.12-2000 ASTM D3578 – 95 EN 455 (1 & 2) …
2021-9-9 · Specifications For Latex Orthopaedic Surgical Gloves - Sterile PHYSICAL DIMENSIONS Glove Size Palm Width (mm) Length (mm) 6.0 76 ± 6 Min.280 6.5 83 ± 6 Min.280 7.0 89 ± 6 Min.280 7.5 95 ± 6 Min.280 8.0 102 ± 6 Min.280 8.5 108 ±6 Min.280 9.0 114 ± 6 Min.280 Thickness Location of Thickness Measurements Double Wall (mm)
2020-4-19 · The gloves shall maintain their properties when stored in a dry condition at temperature not higher than 30°C. Moisture Content Below 0.8% per glove. Shelf-life 5 years from the date of manufacturing. Physical Dimensions Dimension Standards ASTM D3577 EN 455 Length(mm) Min 280 Min 245 (size 5.5) Min 265 (size 6-9) Min. 250 (size 5-5 ...
SQBF09 Qualatrile SENS! Blue Nitrile 9” Powder-Free Gloves ... SQBF09 Qualatrile SENS! Blue Nitrile 9” Powder-Free Gloves Quality Assurance Conformity ASTM D6319 – 10 (2015) ASTM D6124 ASTM D412 U.S. Pharmacopeia-National Formulary (USP-NF) ASTM D573 ANSI ESD S 11.11-1993 ASTM D3577 – 09(2015) ASD STN 11.12-2000 ASTM D3578 – 95 EN 455 (1 & 2) …
2020-5-11 · ACS Material Nitrile Disposable Examination Glove TDS Page 1 Technical Data Sheet Disposable Nitrile Powder-Free Gloves Contact Information: Distributor: ACS Material, LLC. Address: 959 E Walnut St., Suite 100, Pasadena, CA 91106, USA Phone: (866)-227-0656 Fax: (781)-518-0284 E-Mail: contactacsmaterial
NITRILE EXAMINATION GLOVES AQL 1.5 POWDER FREE / … NITRILE EXAMINATION GLOVES AQL 1.5 POWDER FREE / NON STERILE LABELLED CE, MEDICAL GRADE AQL 1.5 Medical Device Class 1: conform with European norms EN 455 1/2/3, EN 374 1/2/3, EN 388, Directive 93/42/EEC and American Standard ASTM D 6319 Individual Safety Equipment: …
2020-12-28 · gloves that fit either hand, paired gloves, and gloves by size. It also provides for packaged sterile or nonsterile or bulk non-sterile nitrile rubber examination gloves. 1.3 This specification is similar to that of Specification D3578 for rubber examination gloves. 1.4 The values stated in SI units are to be regarded as standard.
NITRILE EXAMINATION GLOVES AQL 1.5 POWDER FREE / … NITRILE EXAMINATION GLOVES AQL 1.5 POWDER FREE / NON STERILE LABELLED CE, MEDICAL GRADE AQL 1.5 Medical Device Class 1: conform with European norms EN 455 1/2/3, EN 374 1/2/3, EN 388, Directive 93/42/EEC and American Standard ASTM D 6319 Individual Safety Equipment: …
2017-8-16 · The specification is intended as a reference to the performance and safety of rubber surgical gloves. The safe and proper use of rubber surgical gloves is beyond the scope of this specification.This specification covers certain requirements for packaged
2021-11-11 · Specifications Performance Requirements - AQL ... Glove Specifications Quantity: 4 boxes/ case 50 pairs/ box (by weight) Packaging 71000 Series Latex Surgical Gloves Before Aging After Aging at 100C for 22 hrs Tensile Strength Mpa (minimum) 24 18 Ultimate Elongation % (minimum) 750 560 Stress at 500% elongation (max) 5.5Mpa ...
2016-8-12 · 3 Latex dipped gloves (Type-B of IS 4149) 4 Made from natural rubber. 5 Colour: Orange or Pinkish red 6 The gloves shall have smooth finish and the wrists shall have edges rolled up and reinforced rubber strips 7 Dimensions of glove shall confirm to Table-1 of IS-4149. 8 The gloves shall be free from perforation and other imperfections.
2020-4-22 · IS 4148 R Each glove 4.1.3 Bead of Glove 4.1.3 -do- R 10 Control unit Each Control Unit The Gloves selected for checking dimensions may be used for this purpose. 4.2 & Table 1 Dimensions 4.2 & Table 1 Annex A of IS 4148 R 5 pairs of each size -do- -do- 4.3 Thickness 4.3 IS 4148 R -do- -do- -do- 4.4.1 Tensile strength
2022-6-18 · Medical gloves are one part of an infection-control strategy. Medical gloves are disposable and include examination gloves, surgical gloves, and medical gloves for handling chemotherapy agents ...
2022-6-11 · On December 19, 2016, the FDA published a final rule banning powdered gloves based on the unreasonable and substantial risk of illness or injury to individuals exposed to the powdered gloves ...
Exam gloves are available as either sterile or non-sterile, while surgical gloves are generally sterile. History In 1890 William Stewart Halsted was the first to use sterilized medical gloves when he was at Johns Hopkins University.[4][5] With the publication of germ theory Halsted was using carbolic acid, introduced by Joseph Lister, to ...
2020-12-28 · gloves that fit either hand, paired gloves, and gloves by size. It also provides for packaged sterile or nonsterile or bulk non-sterile nitrile rubber examination gloves. 1.3 This specification is similar to that of Specification D3578 for rubber examination gloves. 1.4 The values stated in SI units are to be regarded as standard.
2020-4-3 · This standard is identical with and has been reproduced from ISO 10282, Single-use sterile rubber surgical gloves — Specification, published by the International Organization for Standardization (ISO). The National Standards Council has endorsed the adoption of the 2002 edition of this standard as a Kenya Standard.
POWDERED & POWDER-FREE Quality Standards • Conforms to ASTM D3577 and EN455 Standards • Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System • Using USP grade absorbable cornstarch • Sterilized by Gamma Ray Irradiation or EtO • Bioburden and sterility tested Glove Sizes • 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, …